QC Results Entry - Purchasing
Quality Control is a major method of providing process control within Deacom, such as when tests are required for Raw Materials received on Purchase Orders. The use of Purchase Order QC testing is an optional feature with a wide array of applications ranging from completely turned off to extremely strict requirements. The QC Result Entry transaction located on the Purchasing menu within the main application is exclusively for the following and directs the user to the main Quality Control Results form and all sub-forms used to add, modify, and complete tests.
- Testing of items received on Purchase Orders.
- The testing of items returned on Sales Orders.
- Entry of Pre-Receipt QC tests prior to Purchase Order receipt.
- Stability Testing - For additional information see the Stability Testing Logic section below.
Quality control is established on an item by item basis via the assignment of Quality Control Groups and Items may contain multiple Quality Control Groups.
Un-Grouping/Re-Grouping Lots
Once Lots are tested as part of a group, when entering results again at a later time, selecting one Lot will automatically select the other already-tested Lots. An example of when this would happen is when testing pallets of material. For Lots already tested, attempting to test that Lot with other untested Lots is not allowed by the system. The Standard report in QC Result Entry now contains an "Un-Group" button, which users that have the security setting "Quality Control -- Un-Group QC" set to yes may use. When this button is clicked, the Lots on the right-hand side of the mover form that have the same QC Groups will be un-grouped and all previously entered QC results will be cleared.
Previously un-grouped lots/QC results can be re-grouped. Results that have been re-grouped will only show new QC results after the re-group has taken place, with no way of viewing the previously entered QC results. See the list below for additional details:
-
Once the lots/QC results have been un-grouped via the "Un-Group" button they will move to the left side of the PO QC Items form.
-
Moving a single previously un-grouped lot will only move that lot back to the right side of the form and not the others. This is because the lots have been ungrouped and no longer have grouped QC results. Users have the option now of moving the other lots that were un-grouped to the right side of the form. In this way, the re-grouping of lots for QC entry is accomplished.
Once moved to the right side of the form, new QC results may be entered and applied. Previously entered QC results will not be displayed on the QC entry form, nor will these previously results be available for display on the C of A document.
Pre-Receipt QC testing
Pre-Receipt QC Testing allows companies to enter Quality Control Test results for items prior to actually receiving the Purchase Order based on the QC specifications provided by Vendors, generally via a Certificate of Analysis. This process is useful in situations where companies have strong relationships with their Vendors and the Vendor has a track record of accurate QC reporting. When Purchase Orders are received, the system checks to see if there is a Pre-Receipt QC record for the Vendor and Part selected on the Purchase Order or for the Purchase Order itself. Deacom security settings associated with normal QC Result Entry process are also enforced when entering Pre-Receipt QC test results.
System Navigation
- Purchasing > QC Result Entry
PO Quality Control pre-filter
Field |
Description |
---|---|
Continue |
Displays the list of PO and SO lines based on the selection criteria. |
Report Type |
Pick list used to determine the kind of report to generate. Options are:
|
Purchase Order |
Search field used to select a specific order on which to perform QC testing. |
Vendor |
Search field used to filter Lots to be tested based on a specific Vendor.
|
Part Number |
Search field used to filter Lots to be tested based on a specific Part.
|
User Lot |
Filters for System Lots to be tested that share the same User Lot.
|
Facility |
Search field used to filter Lots to be tested based on the selected Facility.
|
Facility Group |
Search field used to filter Lots to be tested based on the Facilities that belong to the selected Facility Group.
|
QC Group |
Search field used to filter Lots to be tested based on the Quality Control Group assigned to the Part's Item Master QC/Stability Tests tab. |
QC Test |
Search field used to filter Lots to be tested based on the Quality Control Group that contains the selected Quality Control Test. |
Group Status |
Filters Lots based on the current status of QC Groups. Options are:
|
Test Status |
Filters Lots to be tested based on the current value entered for individual QC tests. Options are:
|
Attribute 1-3 |
Filters Lots to be tested based on the values in their Attribute fields. |
Display |
Pick list used to display Active or Inactive Pre-Receipt QC entries based on the criteria set on the pre-filter.
|
Standard report
Opened via the "Continue" button on the PO Quality Control pre-filter with a "Report Type" of "Standard" selected. The Standard report displays a mover form that lists all lines requiring testing on the left side and allows the use of the move and remove buttons to select lines that will be tested, which are displayed on the right side. Information displayed for the lines listed include order number, QC Group, Vendor, Received date, Part and Description, Lot, and Quantity.
Button |
Description |
---|---|
Continue |
Displays the Quality Control Results form to continue with QC testing. Refer to the Quality Control Results page for field definitions on the forms used for the continuation of this process.
|
Un-Group |
If clicked, the Lots on the right-hand side of the mover form that have the same QC Groups will be un-grouped and all previously entered QC results will be cleared.
|
Pre-Receipt QC report
Opened via the "Continue" button on the PO Quality Control pre-filter with a "Report Type" of "Pre-Receipt QC" selected. The Pre-Receipt QC report lists all previously entered Pre-Receipt QC tests and allows the user to modify those records via the "Modify" button or enter new records via the "Add" button. Information displayed in the report includes Vendor, Part Number, Facility and Facility Group, User Lot, and the Lot Attributes.
Edit Pre-Receipt QC form
Opened via the "Add" or "Modify" buttons on the Pre-Receipt QC report, the Edit Pre-Receipt QC form is used to add or modify Pre-Receipt QC tests and assign the results to specific Purchase Orders, if desired, which are listed in the Pre-Receipt QC Purchase Orders section of the form.
Button/Field/Flag |
Description |
---|---|
Edit QC |
Displays the Quality Control Results form to continue with QC testing. Refer to the Quality Control Results Encyclopedia page for field definitions on the forms used for the continuation of this process. |
Vendor |
Defines the Vendor that will be linked to the Pre-Receipt QC tests. |
Part Number |
Defines the Part Number that will be linked to the Pre-Receipt QC tests. |
Vendor Part |
Defines the Vendor Part Cross Reference associated with the Part Number above. |
Lot Number |
Indicates the specific User Lot number applicable to the entered Pre-Receipt QC tests. |
Facility |
Defines the Facility to which the entered Pre-Receipt QC tests are applicable. |
Facility Group |
Defines the Facility Group to which the entered Pre-Receipt QC tests are applicable. |
Attribute 1-3 |
Indicates the Lot Attributes for the Part Number and Lot specified on this form.
|
Lot Date |
Indicates the Lot date.
|
Active |
If checked, this record is active. Only active records will be evaluated by the system during Purchase Order receipt. |
Add |
Opens the Edit Pre-Receipt QC Purchase Order form, which is used to select a specific Purchase Order for which results may be used. |
Modify |
Opens the Edit Pre-Receipt QC Purchase Order form, which is used to modify the selected Purchase Order for which results may be used. |
Stability Testing Logic
Purchasing stability testing is available via Purchasing > QC Results Entry. The methodology used by Deacom to handle stability testing is handled according to the following logic:
- Date Logic - Lots requiring Stability Testing will automatically be moved into a QC status of Pending QC once the stability test date is reached. The "time clock" for when to place a lot into stability testing starts from the date the lot was previously tested. The field containing the date the lot was previously tested is stored via dtqc5.q5_date. See the data dictionary for additional information on this field. The stability testing time calculation is therefore: last lot QC test date (dtqc5.q5_date) plus number of days listed in the "Stability Days" field on the Edit QC/Stability Tests form.
- QC Status Logic - As indicated in the previous bullet point, lots requiring stability testing will automatically be placed into the Pending QC status when the lot hits it's stability testing date, where it will be unavailable for normal issuing, reserving, and shipping.
- Stability Testing Check Logic: The "Run Automated Processes" checkbox on the Deacom Web Service form needs to be checked in order for the system to automatically check for lots requiring stability testing. When this box is checked, the system will conduct the check when the application is started and once a day at midnight.
Note:
Related Pages
- Entering Purchasing and Stability QC Test Results
- Managing Stability Tests
- Managing Customer Complaints and Returns
- Managing Users and User Security
- Managing Vendors
- Performing Pre-Receipt QC Testing
- Receiving Purchase Orders